Fire
mishaps are one of most common type of accidents that occur in
residential and commercial settings. There are various methods of
avoiding such mishaps. And one of them is installing fire sprinklers
in the building.
The
National Fire Protection Association (NFPA) has laid down various
standards for protecting the commercial settings against accidental
fire mishaps.
If
you have fire sprinkler systems installed in the building, it is
essential to follow NFPA 25 standards. Under this standard,
conducting prior inspection, maintenance, and testing of the
equipment is mandatory. Taking such precautionary steps help in
avoiding any fire accidents in the building.
Below mentioned is a checklist for fire sprinkler maintenance and inspection.
What
to inspect in fire sprinklers?
Remember
fire sprinkler inspection should be carried out on a weekly basis.
- System gauge: The air and water pressure should be monitored when inspecting the system gauge. The readings should match the normal levels.
- Valves: Inspect for leaky valves. These are an important part of the sprinkler system. The valves should be properly sealed for maximum productivity. Signages should be properly installed. These depict the correct way of using the valves.
Monthly
inspection criteria
- Wet gauge: These gauges are found on the wet pipes of the sprinkler system. Inspect for any kind of damage. Replace the sprinkler with a new gauge in case of any physical damage. Also, take readings of the water and air pressure regularly.
- Alarm system valves: External inspection should be performed each month to check for signs of any physical damage.
Quarterly
inspection and maintenance criteria
-
Alarm
equipments: Inspect
the alarm equipments for any signs of potential damage. This should
be done every three months.
- Hydraulic nameplates: This should be in secure space along with the sprinkler rider.
While
conducting fire sprinkler inspection, make
sure that the technicians are licensed. As per the standards set by
NFPA, only certified professionals should be allowed to undertake
inspection activities.